provides a dedicated auxiliary power output providing . Electrical and Environmental Constraints Power Supply Requirements
requires a minimum of 5 VA and a maximum of 26 VA depending on connected external sensor loads.
is its 16 universal inputs, which remove the need for fixed-type input hardware modules. Depending on the specific datasheet revision (e.g., standard legacy 10-bit vs. enhanced 16-bit software conversions), these inputs accommodate an extensive array of sensor types: Input Signal Type Technical Requirements / Specifications Supports 3k Ωcap omega (Ibex) or 10k Ωcap omega (Type II) thermistors for precision temperature monitoring. Dry Contact
| Parameter | Value | | :--- | :--- | | | Discontinued by Honeywell | | Primary Function | Input monitoring device (no control outputs) | | Inputs | 16 universal, 10-bit resolution | | Input Types | Thermistor, dry contact, 0-5 VDC, 4-20 mA, 0-10 VDC, pulse | | Communication | BACnet MS/TP (Master-Slave/Token-Passing) | | Communication Speed | Up to 76.8 Kbps | | Processor | Motorola AZ-60 | | Logic Execution Time | 100 milliseconds (0.1 sec) | | BACnet Compliance | ASC device level, BTL certified | | Operating Environment | -17°C to +70°C, 0-95% RH (non-condensing) | | Dimensions (H x W x D) | 125 x 138 x 36 mm | | Power Supply | 24 VAC, 10 VA max |
The VLC-1600 is designed for robust performance in industrial environments. Below are the key specifications sourced from the official VLC-1600 Datasheet: Power and Environment Consumption: minimum (up to with loads). Environmental: Humidity: , non-condensing. Inputs and Outputs (I/O) vlc 1600 datasheet
(knowing if a door is open or a pump is tripped)
A complete datasheet for a device like the VLC 1600 is a legal and technical document. Here is what you will find in every reputable datasheet.
The front facet is susceptible to contamination. Never touch it. Electrostatic discharge (ESD) protection is mandatory (Human Body Model rating: Class 2, >2000V).
: Supports intelligent wall sensors including the Alerton Microtouch, Microset, and Microset II. provides a dedicated auxiliary power output providing
| Model | Power (mW) | Wavelength (nm) | Package | Key Difference | | :--- | :--- | :--- | :--- | :--- | | | 1600 | 1605 | TO-5.6 | High slope efficiency | | Lumentum 1550-1500 | 1500 | 1550 | Butterfly | Telecom-optimized | | Osram SPL LL90 | 1200 | 905 | TO-56 | Pulsed only, shorter λ | | Thorlabs L1600P5 | 500 | 1600 | TO-56 | Lower power, lower cost |
: EIA-485 (RS-485) over standard Twisted Shielded Pair (TSP) cabling.
The internal logical instruction sequence loops continuously every 100 milliseconds , providing near real-time diagnostics of field conditions.
The power circuit utilizes a . This layout allows fields to wire multiple VLC units back to a single shared transformer, provided that one leg of the 24 VAC secondary side is tied directly to the common earth/panel ground. Depending on the specific datasheet revision (e
: BACnet MS/TP LAN with auto-baud switching at speeds up to 76.8 Kbps (or 115.2 Kbps on newer "-E" models). Programming and Compatibility
Before diving into pinouts and absolute maximum ratings, it is crucial to identify which you are dealing with. Based on market research and technical forums, the two most common interpretations are:
: Auto-baud line switching naturally locks onto host network speeds of 9.6, 19.2, 38.4, 76.8, or 115.2 Kbps .
Certified to bear the European CE mark for electromagnetic emissions and immunity thresholds.